Resultados 1 - 20 de 295
Filtrar
2.
J Neuroeng Rehabil ; 21(1): 35, 2024 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-38454427

RESUMEN

BACKGROUND: Persons with a transfemoral amputation (TFA) often experience difficulties in daily-life ambulation, including an asymmetrical and less stable gait pattern and a greater cognitive demand of walking. However, it remains unclear whether this is effected by the prosthetic suspension, as eliminating the non-rigid prosthetic connection may influence stability and cortical activity during walking. Spatiotemporal and stability-related gait parameters, as well as cortical activity during walking, were evaluated between highly active individuals (MFC-level K3-4) with a TFA and able-bodied (AB) persons, and between persons with a bone-anchored prosthesis (BAP) and those with a socket-suspended prosthesis (SSP). METHODS: 18 AB persons and 20 persons with a unilateral TFA (10 BAP-users, 10 SSP-users) walked on a treadmill at their preferred speed. Spatiotemporal and margin of stability parameters were extracted from three-dimensional movement recordings. In addition, 126-channel electroencephalogram (EEG) was recorded. Brain-related activity from several cortical areas was isolated using independent component analysis. Source-level data were divided into gait cycles and subjected to time-frequency analysis to determine gait-cycle dependent modulations of cortical activity. RESULTS: Persons with TFA walked with smaller and wider steps and with greater variability in mediolateral foot placement than AB subjects; no significant differences were found between BAP- and SSP-users. The EEG analysis yielded four cortical clusters in frontal, central (both hemispheres), and parietal areas. No statistically significant between-group differences were found in the mean power over the entire gait cycle. The event-related spectral perturbation maps revealed differences in power modulations (theta, alpha, and beta bands) between TFA and AB groups, and between BAP- and SSP-users, with largest differences observed around heel strike of either leg. CONCLUSIONS: The anticipated differences in gait parameters in persons with TFA were confirmed, however no significant effect of the fixed suspension of a BAP was found. The preliminary EEG findings may indicate more active monitoring and control of stability in persons with TFA, which appeared to be timed differently in SSP than in BAP-users. Future studies may focus on walking tasks that challenge stability to further investigate differences related to prosthetic suspension.


Asunto(s)
Amputados , Miembros Artificiales , Prótesis Anclada al Hueso , Humanos , Marcha , Amputación Quirúrgica , Caminata , Fenómenos Biomecánicos , Diseño de Prótesis
3.
Med Eng Phys ; 123: 104091, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38365342

RESUMEN

This short communication presents the gait1415+2 musculoskeletal model, that has been developed in OpenSim to describe the lower-extremity of a human subject with transfemoral amputation wearing a generic lower-limb bone-anchored prosthesis. The model has fourteen degrees of freedom, governed by fifteen musculotendon units (placed at the contralateral and residual limbs) and two generic actuators (one placed at the knee joint and one at the ankle joint of the prosthetic leg). Even though the model is a simplified abstraction, it is capable of generating a human-like walking gait and, specifically, it is capable of reproducing both the kinematics and the dynamics of a person with transfemoral amputation wearing a bone-anchored prosthesis during normal level-ground walking. The model is released as support material to this short communication with the final goal of providing the scientific community with a tool for performing forward and inverse dynamics simulations, and for developing computationally-demanding control schemes based on artificial intelligence methods for lower-limb prostheses.


Asunto(s)
Amputados , Miembros Artificiales , Prótesis Anclada al Hueso , Humanos , Inteligencia Artificial , Caminata , Marcha , Fenómenos Biomecánicos , Diseño de Prótesis
4.
Proc Inst Mech Eng H ; 238(4): 412-422, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38415608

RESUMEN

Percutaneous osseointegrated implants for individuals with lower limb amputation can increase mobility, reduce socket related pain, and improve quality of life. It would be useful to have an evaluation method to assess the interface between bone and implant. We assessed outpatient radiographs from the Intraosseous Transcutaneous Amputation Prosthesis clinical trial using an interface scoring system which summed and weighted equally measures of implant collar cortical ongrowth and radiolucency along the implant stem/bone interface. Radiographs from 12 participants with unilateral transfemoral amputations (10 males, 2 females, mean age = 43.2, SD = 7.4 years) in the clinical trial from cohort I (implanted in 2008/09) or cohort II (implanted in 2013/14) were collated (mean image span = 7.2, SD = 2.4 years), scale normalised, zoned, and measured in a repeatable way. Interface scores were calculated and then compared to clinical outcomes. Explanted participants received the lowest interface scores. A higher ratio of stem to residuum and shorter residuum's produced better interface scores and there was an association (weak correlation) between participants with thin cortices and the lowest interface scores. A tapered, cemented, non curved stem may provide advantageous fixation while stem alignment did not appear critical. In summary, the interface score successfully demonstrated a non-invasive evaluation of percutaneous osseointegrated implants interfaces when applied to the Intraosseous Transcutaneous Amputation Prosthesis clinical trial. The clinical significance of this work is to identify events leading to aseptic or septic implant removal and contribute to clinical guidelines for monitoring rehabilitation, design and surgical fixation choices.


Asunto(s)
Amputados , Miembros Artificiales , Prótesis Anclada al Hueso , Masculino , Femenino , Humanos , Adulto , Implantación de Prótesis , Oseointegración , Calidad de Vida , Fémur/cirugía , Amputados/rehabilitación , Amputación Quirúrgica , Diseño de Prótesis , Resultado del Tratamiento
5.
Med Eng Phys ; 124: 104097, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38418026

RESUMEN

This proof of concept study presents a method to collect and analyse kinetic data from one participant with a transfemoral amputation fitted with a percutaneous osseointegrated implant walking on a level and sloped treadmill. We describe the construction of and results from a bespoke wireless six axis load cell built into one participant's prosthetic assembly. The load cell does not clinically compromise the participant in any way and is an initial milestone in the development of a light-weight wireless load cell for use with percutaneous osseointegrated implants. In this case, it is the first time that kinetic data from a participant fitted with an Intraosseous Transcutaneous Amputation Prosthesis has been published. We propose that the data can be used to model the load transfer to the host bone, with several clinically significant applications. The raw dynamic data are made available and quasi-static load cases for each functional phase of gait are presented. Peak forces obtained in the medio-lateral (X), cranio-caudal (Y) and antero-posterior (Z) axes over level ground respectively were -243.8 N (0.24 BW), 1321.5 N (1.31 BW) and -421.8 N (0.42 BW); uphill were -141.0 N (0.14 BW), 1604.2 N (1.59 BW), -498.1 N (0.49 BW); downhill were -206.0 N (0.20 BW), 1103.9 N (1.09 BW), -547.2 N (0.54 BW). The kinetics broadly followed able bodied gait patterns with some gait strategies consistent in participants with other implant designs or prosthetic socket connections, for example offloading the artificial limb downhill.


Asunto(s)
Amputados , Miembros Artificiales , Prótesis Anclada al Hueso , Humanos , Caminata , Marcha , Amputación Quirúrgica , Diseño de Prótesis , Fenómenos Biomecánicos
6.
Sci Rep ; 14(1): 627, 2024 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-38182598

RESUMEN

This study evaluated the peri-implant tissues under normal conditions and under the influence of experimental peri-implantitis (EPI) in osseointegrated implants installed in the maxillae of rats treated with oncologic dosage of zoledronate. Twenty-eight senescent female rats underwent the extraction of the upper incisor and placement of a titanium dental implant (DI). After eight weeks was installated a transmucosal healing screw on DI. After nine weeks, the following groups were formed: VEH, ZOL, VEH-EPI and ZOL-EPI. From the 9th until the 19th, VEH and VEH-EPI groups received vehicle and ZOL and ZOL-EPI groups received zoledronate. At the 14th week, a cotton ligature was installed around the DI in VEH-EPI and ZOL-EPI groups to induce the EPI. At the 19th week, euthanasia was performed, and the maxillae were processed so that at the implanted sites were analyzed: histological aspects and the percentage of total bone tissue (PTBT) and non-vital bone tissue (PNVBT), along with TNFα, IL-1ß, VEGF, OCN and TRAP immunolabeling. ZOL group presented mild persistent peri-implant inflammation, higher PNVBT and TNFα and IL-1ß immunolabeling, but lower for VEGF, OCN and TRAP in comparison with VEH group. ZOL-EPI group exhibited exuberant peri-implant inflammation, higher PNVBT and TNFα and IL-1ß immunolabeling when compared with ZOL and VEH-EPI groups. Zoledronate disrupted peri-implant environment, causing mild persistent inflammation and increasing the quantity of non-vital bone tissue. Besides, associated with the EPI there were an exacerbated inflammation and even greater increase in the quantity of non-vital bone around the DI, which makes this condition a risk factor for medication-related osteonecrosis of the jaws.


Asunto(s)
Prótesis Anclada al Hueso , Osteonecrosis , Periimplantitis , Femenino , Animales , Ratas , Periimplantitis/etiología , Ácido Zoledrónico/efectos adversos , Factor de Necrosis Tumoral alfa , Factor A de Crecimiento Endotelial Vascular , Inflamación , Interleucina-1beta , Maxilares
7.
Eur J Orthop Surg Traumatol ; 34(2): 885-892, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37750975

RESUMEN

PURPOSE: To evaluate the implant survival rate, mechanical complications, and reported patient outcomes of bone-anchored prostheses for patients with lower limb amputation in France after 1-15 years of follow-up. METHODS: This retrospective cohort study included patients who underwent surgery at a single center in France between 2007 and 2021. The primary outcomes were the implant survival rate and functional scores assessed by the Questionnaire for Transfemoral Amputees (Q-TFA). Secondary outcomes were adverse events that occurred during follow-up. RESULTS: The cohort consisted of 20 bone-anchored prostheses in 17 patients. The main level of amputation was transfemoral (82%, n = 14). The main reason for amputation was trauma (n = 15). The mean age at amputation was 32 (range 15-54) years, and the mean age at the first stage of osseointegration was 41 (range 21-58) years. The Kaplan-Meier survival curve showed respective survival rates of 90%, 70%, and 60% at 2, 10, and 15 years. All Q-TFA scores were significantly improved at last the follow-up. Eleven patients (65%) experienced mechanical complications. In total, 37 infectious events occurred in 13 patients (76%), mainly comprising stage 1 infections (68%, n = 25). Only two cases of septic loosening occurred (12%), leading to implant removal. CONCLUSION: This is the first French cohort of bone-anchored prostheses and among the series with the longest follow-up periods. The findings indicate that bone-anchored prostheses are safe and reliable for amputee patients who have difficulties with classic prostheses.


Asunto(s)
Miembros Artificiales , Prótesis Anclada al Hueso , Humanos , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Tasa de Supervivencia , Estudios Retrospectivos , Amputación Quirúrgica/efectos adversos , Oseointegración , Miembros Artificiales/efectos adversos , Extremidad Inferior/cirugía , Medición de Resultados Informados por el Paciente , Diseño de Prótesis
8.
Support Care Cancer ; 31(12): 641, 2023 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-37851170

RESUMEN

PURPOSE: To investigate the survival rate in implants placement in irradiated and non-irradiated bone in patients undergoing head and neck cancer (HNC) treatment. We focused on the consequences of the main complications, such as osteoradionecrosis and peri-implantitis. METHODS: An electronic search conducted by PRISMA protocol was performed. Full texts were carefully assessed, and data were assimilated into a tabular form for discussion and consensus among the expert panel. The quality assessment and the risk of bias are verified by Joanna Briggs Institute checklist (JBI) and The Newcastle-Ottawa Scale (NOS), and Risk of Bias in Non-Randomized Studies of Interventions (ROBINS-I) assessment tool. RESULTS: A total of 452 records were identified in the based on our PICOs strategy and after screening, 19 articles were included in the descriptive analysis of the review. Totaling 473 implants placed in irradiated and non-irradiated bone, and 31.6% of the patients were over 60 years of age. 57.9%) performed implant placement in a period of 12 months or more after the ending of radiotherapy. Only 5 studies had a follow-up period longer than 5 years after implant placement, of which three were used for the meta-analysis. In the meta-analysis of 5-year survival rate, analysis of implants in irradiated bone was assessed; a random effect model was used and a weighted proportion (PP) of 93.13% (95% CI: 87.20-99.06; p < 0.001), and in the 5-year survival rate, analysis of implants in non-irradiated bone was analysed; a fixed effect model was used and a weighted proportion (PP) of 98.52% survival (95% CI: 97.56-99.48, p < 0.001). CONCLUSIONS: Survival rates of implants placed in irradiated bone are clinically satisfactory after a follow-up of 5 years, with a fewer percentage than in implants placed in non-irradiated bone after metanalyses performed.


Asunto(s)
Prótesis Anclada al Hueso , Neoplasias de Cabeza y Cuello , Humanos , Persona de Mediana Edad , Anciano , Neoplasias de Cabeza y Cuello/radioterapia
9.
Acta Orthop ; 94: 499-504, 2023 10 10.
Artículo en Inglés | MEDLINE | ID: mdl-37830879

RESUMEN

BACKGROUND AND PURPOSE: Little is known about the activities of daily living (ADL) of patients with a bone-anchored prosthesis (BAP). We aimed to objectively measure ADL without and with BAP during standard care of follow-up. Our secondary aim was to measure mobility and walking ability. PATIENTS AND METHODS: Patients aged 18-99 years who underwent surgery for transfemoral or transtibial BAP between September 11, 2017, and February 11, 2021, were eligible for inclusion in this retrospective case series of patients with socket prosthesis. ADL was measured with a continuous recording activity monitor (hours [h]) before surgery, and at 6, 12, and 24 months with BAP. Mobility and walking ability were assessed by the Timed Up and Go test (TUG) (seconds [s]) and 6 Minute Walk Test (6MWT) (meters [m]), respectively. RESULTS: 48 of the 57 eligible patients provided informed consent and were included. Their age was 59 (1st quartile to 3rd quartile 51-63) years. Total daily activity before BAP was 1.6 h (0.82-2.1) and increased to 2.1 h (1.4-2.5) at 6, 2.0 h (1.5-2.7) at 12, and 2.7 h (2.0-3.3) at 24 months with BAP. Daily walking increased from 1.3 h (0.79-1.9) before BAP to 1.8 h (1.6-2.3) at 6, to 1.7 h (1.2-2.4) at 12, and 2.0 h (1.6-2.6) at 24 months. Median TUG decreased from 12 s (9.1-14) before BAP to 8.9 s (7.7-10) at 24 months. Mean 6MWT increased from 272 m (SD 92) before BAP to 348 m (SD 68) at 24 months. CONCLUSION: Objective measurements on ADL positively changed in patients with BAP. This effect was also seen in mobility and walking ability at 24 months.


Asunto(s)
Amputados , Miembros Artificiales , Prótesis Anclada al Hueso , Humanos , Actividades Cotidianas , Estudios de Seguimiento , Estudios Retrospectivos , Equilibrio Postural , Estudios de Tiempo y Movimiento , Extremidad Inferior/cirugía , Caminata
10.
Clin Biomech (Bristol, Avon) ; 110: 106099, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37832468

RESUMEN

BACKGROUND: Restoring the ability to walk with a prosthesis is considered a fundamental rehabilitation goal after transfemoral amputation. An essential prerequisite for achieving this goal is adequate force transmission between the prosthesis and the body. Does bone anchorage of an artificial limb permit a more normal force transmission? METHODS: Data of 15 healthy subjects, nine amputees fitted with bone-anchored prostheses, nine amputees using socket prostheses, and 18 patients with a total hip replacement were included in this multicenter, observational study. Ground reaction force was measured using Kistler force plates. Kinematics was recorded with 12 Vicon Bonita cameras. Subjects were instructed to walk at three different speeds: first at their self-selected, then at slow, and finally at fast speed. FINDINGS: Self-selected walking speeds of subject groups were significantly different, osseointegrated amputees walked the slowest. The lowest ground reaction force was measured for osseointegrated amputees on the prosthetic side, who also showed the highest force on their contralateral side. Patients with hip replacements showed values similar as healthy subjects. The vertical center of gravity movement was specific for each subject group. INTERPRETATION: The force transmission capacity of the bone-anchored prosthetic leg is limited during walking and is lower than both in socket prostheses users without symptoms and patients with total hip replacement. Therefore, active amputees well fitted with a socket prosthesis who consider a transition to bone-anchorage should be advised that their walking speed may decrease with high probability, and that their self-selected walking speed may even be slower than 3 km/h.


Asunto(s)
Amputados , Artroplastia de Reemplazo de Cadera , Miembros Artificiales , Prótesis Anclada al Hueso , Humanos , Amputados/rehabilitación , Caminata , Extremidad Inferior
11.
BMC Oral Health ; 23(1): 756, 2023 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-37833674

RESUMEN

BACKGROUND: Today dental implants represent an effective therapy in case of partial or total edentulism, with an excellent success rate. Despite the results obtained, there may be biological or mechanical complications during the therapy, which lead to the loss of the implant. This systematic review aims to evaluate the current state of the art in the literature on techniques used for the removal of dental implants. Various aspects will be analyzed, such as the success of the technique, any complications, and the advantages and disadvantages of their use. METHODS: Two reviewers conducted a literature analysis (PubMed, Embase, Web of Science) of the last 20 years (2003-2023). The main criterion analyzed was the success of the technique, while secondary outcomes such as complications and risks of the technique were also analyzed. 258 articles were identified in the various search databases. 42 eligible articles were subsequently identified after an article screening. Only 18 full texts were subsequently included in the review. RESULTS: A total of 18 articles were selected and 1142 implants and 595 patients were included. The main techniques used were the Counter-Torque Ratchet Technique (CTRT), Piezoelectric bone surgery (PBS), trephine drills, carbide burs, Erbium, Chromium, Yttrium, Scandium, Gallium, Garnett (Er:Cr:YSGG) laser and carbon dioxide (CO2) laser. Combined uses of techniques have been identified such as: PBS and trephine burs or carbide burs, trephine burs with the use of a 3d-printed guide, CTRT and trephine burs. The technique with the highest success rate, less morbidity for the patient, and less removal of bone appears to be the CTRT. CONCLUSIONS: The use of conservative techniques, especially CTRT, in bone removal is useful to allow for immediate implant placement in the removal area. However, further studies with a high sample size are needed to be performed on all techniques, particularly new randomized controlled trials (RCTs) that allow for the analysis of the success of alternative techniques such as Laser and Piezosurgery, which appear to be very promising.


Asunto(s)
Prótesis Anclada al Hueso , Implantes Dentales , Láseres de Estado Sólido , Humanos , Implantación Dental Endoósea/métodos , Itrio
12.
Ann Med ; 55(2): 2255206, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37677026

RESUMEN

PURPOSE: Many individuals with a lower limb amputation experience problems with the fitting of the socket of their prosthesis, leading to dissatisfaction or device rejection. Osseointegration (OI)- the implantation of a shaft directly interfacing with the remaining bone- is an alternative for these patients. In this observational study, we investigated how bone anchoring influences neuromuscular parameters during balance control in a patient with a unilateral transfemoral amputation. MATERIAL AND METHODS: Center of pressure (CoP) and electromyography (EMG) signals from muscles controlling the hip and the ankle of the intact leg were recorded during quiet standing six months before and one and a half years after this patient underwent an OI surgery. Results were compared to a control group of nine able-bodied individuals. RESULTS: Muscle co-activation and EMG intensity decreased after bone anchoring, approaching the levels of able-bodied individuals. Muscle co-activation controlling the ankle decreased in the high-frequency range, and the EMG intensity spectrum decreased in the lower-frequency range for all muscles when vision was allowed. With eyes closed, the ankle extensor muscle showed an increased EMG intensity in the high-frequency range post-surgery. CoP length increased in the mediolateral direction of the amputated leg. CONCLUSIONS: These findings point to shifts in the patient's neuromuscular profile towards the one of able-bodied individuals.


Asunto(s)
Amputados , Prótesis Anclada al Hueso , Humanos , Oseointegración , Músculo Esquelético , Electromiografía
13.
PLoS One ; 18(8): e0290347, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37624860

RESUMEN

Antimicrobial blue light (aBL) is an attractive option for managing biofilm burden at the skin-implant interface of percutaneous osseointegrated (OI) implants. However, marketed aBL devices have both structural and optical limitations that prevent them from being used in an OI implant environment. They must be handheld, preventing even irradiation of the entire skin-implant interface, and the devices do not offer sufficient optical power outputs required to kill biofilms. We present the developmental process of a unique aBL device that overcomes these limitations. Four prototypes are detailed, each being a progressive improvement from the previous iteration as we move from proof-of-concept to in vivo application. Design features focused on a cooling system, LED orientation, modularity, and "sheep-proofing". The final prototype was tested in an in vivo OI implant sheep model, demonstrating that it was structurally and optically adequate to address biofilm burdens at the skin-implant of percutaneous OI implants. The device made it possible to test aBL in the unique OI implant environment and compare its efficacy to clinical antibiotics-data which had not before been achievable. It has provided insight into whether or not continued pursual of light therapy research for OI implants, and other percutaneous devices, is worthwhile. However, the device has drawbacks concerning the cooling system, complexity, and size if it is to be translated to human clinical trials. Overall, we successfully developed a device to test aBL therapy for patients with OI implants and helped progress understanding in the field of infection management strategies.


Asunto(s)
Antiinfecciosos , Prótesis Anclada al Hueso , Humanos , Animales , Ovinos , Prótesis e Implantes , Luz , Antibacterianos/farmacología , Antibacterianos/uso terapéutico
14.
Otol Neurotol ; 44(7): e504-e511, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37317481

RESUMEN

OBJECTIVE: To evaluate and compare perioperative outcomes of percutaneous bone-anchored hearing implant (BAHI) surgery in syndromic and nonsyndromic pediatric patients. STUDY DESIGN: Retrospective cohort study. SETTING: McGill University Health Centre in Montreal, Quebec, Canada. PATIENTS: Forty-one pediatric patients (22 syndromic, 19 nonsyndromic) who underwent percutaneous BAHI surgery between March 2008 and April 2021. INTERVENTION: Percutaneous BAHI surgery. MAIN OUTCOME MEASURES: Patient demographics (age at surgery, gender, implant laterality), operative information (American Society of Anesthesia [ASA] score, anesthesia type, surgical technique, implant/abutment characteristics), and postoperative outcomes (implant stability, soft tissue integrity, surgical revisions, implant failure). RESULTS: The most frequent syndromes among implanted patients were Treacher Collins (27.3%), Goldenhar (13.6%), Trisomy 21 (13.6%), and Nager (9.1%). Syndromic patients were more frequently given higher ASA scores: 2 ( p = 0.003) and 3 ( p = 0.014). All cases of implant extrusion were in syndromic patients: two posttraumatic and two failures to osseointegrate. Nine (40.9%) syndromic patients experienced a Holgers Grade 4 skin reaction at one of their postoperative follow-up visits as compared to 0% of nonsyndromic patients ( p < 0.001). Implant stability was similar between cohorts at all postoperative time-points, except for significantly greater nonsyndromic implant stability quotient scores at 16 weeks ( p = 0.027) and 31+ weeks ( p = 0.016). CONCLUSIONS: Percutaneous BAHI surgery is a successful rehabilitation option in syndromic patients. However, it presents a relatively higher incidence of implant extrusion and severe postoperative skin reactions as compared to nonsyndromic patients. In light of these findings, syndromic patients may be great candidates for novel transcutaneous bone conduction implants.


Asunto(s)
Prótesis Anclada al Hueso , Audífonos , Pérdida Auditiva , Humanos , Niño , Pérdida Auditiva/cirugía , Pérdida Auditiva/etiología , Audífonos/efectos adversos , Estudios Retrospectivos , Audición , Prótesis Anclada al Hueso/efectos adversos , Resultado del Tratamiento , Anclas para Sutura
15.
Clin Rehabil ; 37(12): 1670-1683, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37350084

RESUMEN

OBJECTIVE: This study presents the walking abilities of participants fitted with transfemoral bone-anchored prostheses using a total of 14 gait parameters. DESIGN: Two-centre retrospective cross-sectional comparative study. SETTING: Research facilities equipped with tridimensional motion capture systems. PARTICIPANTS: Two control arms included eight able-bodied participants arm (54 ± 9 years, 1.75 ± 0.07 m, 76 ± 7 kg) and nine participants fitted with transfemoral socket-suspended prostheses arm (59 ± 9 years, 1.73 ± 0.07 m, 80 ± 16 kg). The intervention arm included nine participants fitted with transfemoral bone-anchored prostheses arm (51 ± 13 years, 1.78 ± 0.09 m, 87.3 ± 16.1 kg). INTERVENTION: Fitting of transfemoral bone-anchored prostheses. MAIN MEASURES: Comparisons were performed for two spatio-temporal, three spatial and nine temporal gait parameters. RESULTS: The cadence and speed of walking were 107 ± 6 steps/min and 1.23 ± 0.19 m/s for the able-bodied participants arm, 88 ± 7 steps/min and 0.87 ± 0.17 m/s for the socket-suspended prosthesis arm, and 96 ± 6 steps/min and 1.03 ± 0.17 m/s for bone-anchored prosthesis arm, respectively. Able-bodied participants and bone-anchored prosthesis arms were comparable in age, height, and body mass index as well as cadence and speed of walking, but the able-bodied participant arm showed a swing phase 31% shorter. Bone-anchored and socket-suspended prostheses arms were comparable for age, height, mass, and body mass index as well as cadence and speed of walking, but the bone-anchored prosthesis arm showed a step width and duration of double support in seconds 65% and 41% shorter, respectively. CONCLUSIONS: Bone-anchored and socket-suspended prostheses restored equally well the gait parameters at a self-selected speed. This benchmark data provides new insights into the walking ability of individuals using transfemoral bionics bone-anchored prostheses.


Asunto(s)
Amputados , Miembros Artificiales , Prótesis Anclada al Hueso , Humanos , Amputación Quirúrgica , Estudios Retrospectivos , Estudios Transversales , Marcha , Caminata , Fenómenos Biomecánicos , Diseño de Prótesis
16.
Clin Biomech (Bristol, Avon) ; 105: 105954, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37075546

RESUMEN

BACKGROUND: For patients with transfemoral amputation experiencing issues with their sockets, bone-anchored prosthesis systems are an alternative and sometimes the only way to be mobile and independent. The present cross-sectional study aimed to investigate the gait performance and quality of life of a group of patients treated with bone-anchored systems compared to those of participants treated with a conventional socket-suspended prosthesis. METHODS: A total of 17 participants with a socket-suspended and 20 with a bone-anchored prosthesis were included. Gait patterns were examined for symmetry, and performance was assessed using the six-minute walk test and the timed "Up & Go" test. Magnetic resonance imaging was performed to detect signs of osteoarthritis in both hips. Mobility in everyday life and quality of life were assessed using questionnaires. FINDINGS: There were no differences between the groups regarding the quality of life, daily mobility, and gait performance. The step width was significantly higher for the patients using socket-suspended prosthesis. The socket-suspended group showed a significant asymmetry regarding the step length. In the socket-suspended group, the prosthetic leg showed significantly higher cartilage abrasion than the contralateral leg did. INTERPRETATION: Large differences in the measured outcomes in both groups illustrate the very different capabilities of the individual participants, which is apparently not primarily determined by the type of treatment. For patients who are satisfied with the socket treatment and perform well, bone-anchored prosthesis systems may not necessarily improve their functional capabilities and perceived quality of life.


Asunto(s)
Miembros Artificiales , Prótesis Anclada al Hueso , Humanos , Diseño de Prótesis , Calidad de Vida , Estudios Transversales , Amputación Quirúrgica , Oseointegración
17.
Gait Posture ; 103: 12-18, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37075553

RESUMEN

BACKGROUND: A transfemoral bone-anchored prosthesis (BAP) is an alternative for the conventional socket-suspended prosthesis (SSP) in persons suffering from socket-related problems. In these persons, it has been demonstrated to reduce oxygen consumption during walking, which could be related to centre of mass (CoM) and trunk dynamics. However, it remains uncertain whether the same comparative findings are found in SSP-users without any socket-related problems. RESEARCH QUESTION: Do oxygen consumption, CoM and trunk dynamics during walking differ between satisfied transfemoral SSP- and BAP-users and able-bodied individuals (AB); and are CoM and trunk dynamics and pistoning potential determinants of oxygen consumption? METHODS: Oxygen consumption was measured while participants walked on a treadmill at preferred speed, 30 % slower, and 30 % faster. At preferred speed, we also evaluated CoM deviation, root-mean-square values (RMS) of mediolateral (ML) CoM and trunk excursions, and pistoning. In the prosthetic users, we evaluated whether oxygen consumption, CoM and trunk dynamics, and pistoning were associated. RESULTS: We included BAP-users (n = 10), SSP-users (n = 10), and AB (n = 10). SSP-users demonstrated higher oxygen consumption, CoM and trunk RMS ML in comparison to AB during walking. BAP-users showed intermediate results between SSP-users and AB, yet not significantly different from either group. Greater CoM and trunk excursions were associated with higher oxygen consumption; in the SSP-users a greater degree of pistoning, in turn, was found to associate with larger trunk RMS ML. SIGNIFICANCE: Our results indicate that satisfied SSP-users have increased oxygen consumption compared to AB subjects and use compensatory movements during walking. An assessment of CoM and trunk dynamics, and pistoning during walking may be considered for evaluating whether an individual SSP-user could possibly benefit from a BAP, in addition to the currently used functional tests for evaluating eligibility. This might lead to a larger group of persons with a transfemoral SSP benefiting from this technology.


Asunto(s)
Amputados , Miembros Artificiales , Prótesis Anclada al Hueso , Humanos , Estudios Transversales , Marcha , Caminata , Consumo de Oxígeno , Diseño de Prótesis
18.
Medicina (Kaunas) ; 59(3)2023 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-36984430

RESUMEN

Background and Objectives: The treatment of transfemoral amputees using osseointegrated implants for prosthetic anchorage requires accurate implant positioning when using threaded bone-anchoring implants due to the curvature of the femur and the risk of cortical penetration in misaligned implants. This study investigated the accuracy and precision in implant positioning using additively manufactured case-specific positioning guides. Materials and Methods: The geometry and density distribution of twenty anatomic specimens of human femora were assessed in quantitative computed tomography (QCT) scanning. The imaging series were used to create digital 3D specimen models, preoperatively plan the optimal implant position and manufacture specimen-specific positioning guides. Following the surgical bone preparation and insertion of the fixture (threaded bone-anchoring element) (OPRA; Integrum AB, Mölndal, Sweden), a second QCT imaging series and 3D model design were conducted to assess the operatively achieved implant position. The 3D models were registered and the deviations of the intraoperatively achieved implant position from the preoperatively planned implant position were analyzed as follows. The achieved, compared to the planned implant position, was presented as resulting mean hip abduction or adduction (A/A) and extension or flexion (E/F) and mean implant axis offset in medial or lateral (M/L) and anterior or posterior (A/P) direction measured at the most distal implant axis point. Results: The achieved implant position deviated from the preoperative plan by 0.33 ± 0.33° (A/A) and 0.68 ± 0.66° (E/F) and 0.62 ± 0.55 mm (M/L) and 0.68 ± 0.56 mm (A/P), respectively. Conclusions: Using case-specific guides, it was feasible to achieve not only accurate but also precise positioning of the implants compared to the preoperative plan. Thus, their design and application in the clinical routine should be considered, especially in absence of viable alternatives.


Asunto(s)
Prótesis Anclada al Hueso , Humanos , Amputación Quirúrgica , Implantación de Prótesis , Prótesis e Implantes , Fémur/cirugía , Imagenología Tridimensional
19.
J Mech Behav Biomed Mater ; 141: 105787, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36989873

RESUMEN

While cementless implants are now widely used clinically, implant debonding still occur and is difficult to anticipate. Assessing the biomechanical strength of the bone-implant interface can help improving the understanding of osseointegration phenomena and thus preventing surgical failures. A dedicated and standardized implant model was considered. The samples were tested using a mode III cleavage device to assess the mechanical strength of the bone-implant interface by combining experimental and numerical approaches. Four rough (Sa = 24.5 µm) osseointegrated coin-shaped implants were left in sheep cortical bone during 15 weeks of healing time. Each sample was experimentally rotated at 0.03°/sec until complete rupture of the interface. The maximum values of the torque were comprised between 0.48 and 0.72 N m, while a significant increase of the normal force from 7-12 N to 31-43 N was observed during the bone-implant interface debonding, suggesting the generation of bone debris at the bone-implant interface. The experimental results were compared to an isogeometric finite element model describing the adhesion and debonding phenomena through a modified Coulomb's law, based on a varying friction coefficient to represent the transition from an unbroken to a broken bone-implant interface. A good agreement was found between numerical and experimental torques, with numerical friction coefficients decreasing from 8.93 to 1.23 during the bone-implant interface rupture, which constitutes a validation of this model to simulate the debonding of an osseointegrated bone-implant interface subjected to torsion.


Asunto(s)
Prótesis Anclada al Hueso , Implantes Dentales , Animales , Ovinos , Oseointegración , Fenómenos Mecánicos , Interfase Hueso-Implante , Prótesis e Implantes , Análisis de Elementos Finitos , Fenómenos Biomecánicos
20.
Clin Ter ; 174(2): 180-184, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36920136

RESUMEN

Introduction: New techniques, surgical protocols, dental implant designs, and prosthetic rehabilitation have been used in dentistry, most of which have yielded good results in the literature. This retrospective survey assessed the clinical results of patients rehabilitated with dental implants between January 2011 and December 2021. Load protocols (immediate and conventional), types of connections of the installed implants, external hexagon (EH), and cone morse (MC) were evaluated. Material and methods: Two evaluators were selected and calibrated to perform the analyses. The inclusion criteria were records with complete and legible information of patients rehabilitated with dental implants who were followed for at least 1 year after rehabilita-tion. The medical records were divided into two groups, G1 (implants with conventional load) and G2 (implants with immediate load), and further subdivided according to implant type. Information about the rehabilitation failures was noted and descriptive statistics of the results were obtained. Results: Among the 432 evaluated medical records of patients rehabilitated with implants, the study included 319 records: 223 from women and 96 from men, aged 20-79 years. In total, data were available on 1,227 implants with dimensions of 10-13 mm and diameters of 3.75-4 mm. The G1 (n=1.188) survival rates were 94.95% for EH implants and 99.5% for MC implants. In G2 (n=39), the survival rates were 93.75% for EH implants and 91.3% for MC implants. The implant survival rates were relatively high among all groups evaluated; however, the discrepancy between the number of implants in the groups may compromise the comparison between them. Understanding and respecting the biomechanical and technical principles of each protocol was the main factor influencing the success of rehabilitation. Conclusion: The results of this study showed that, according to medical records, rehabilitation with dental implants showed excellent results regardless of the connection type (EH or MC) or loading protocol (conventional or immediate). The two loading protocols and two connection types had excellent results and scientific support. Therefore, the choice should be based on the clinical needs of each patient.


Asunto(s)
Prótesis Anclada al Hueso , Implantes Dentales , Masculino , Humanos , Femenino , Estudios Retrospectivos , Implantación Dental Endoósea , Estudios de Seguimiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...